Browse technical resources about industrial BESS, battery packs, C&I storage, thermal management, and fire safety.
HOME / Micro Photovoltaic Inverter Characteristics - KKA Industrial Storage
A solar inverter is a type of electrical converter which converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network.
A large number of PV inverters is available on the market – but the devices are classified on the basis of three important characteristics: power, DC-related design, and circuit topology. 1. Power The available power output starts at two kilowatts and extends into the megawatt range.
As introduced in Chap. 1, the photovoltaic (PV) inverters are the key link responsible for converting solar energy into electricity. The topology and control technology directly determine the investment costs, conversion efficiency, and output performance of the PV generation system. There are many topologies for connecting PV modules to the grid.
Typical outputs are 5 kW for private home rooftop plants, 10 – 20 kW for commercial plants (e.g., factory or barn roofs) and 500 – 800 kW for use in PV power stations. 2. Module wiring The DC-related design concerns the wiring of the PV modules to the inverter.
In order to couple a solar inverter with a PV plant, it's important to check that a few parameters match among them. Once the photovoltaic string is designed, it's possible to calculate the maximum open-circuit voltage (Voc,MAX) on the DC side (according to the IEC standard).
It should be noted that the power, DC voltage, and AC current are the basic control objectives for the commonly used PV inverter, which merely satisfy the basic normal operation requirements. However, to meet the requirements of commercialization of PV power generation, some special performance indexes have to be satisfied.
Stage 1, stage 2, and stage 3 form the typically cascaded control structure. It should be noted that the power, DC voltage, and AC current are the basic control objectives for the commonly used PV inverter, which merely satisfy the basic normal operation requirements.
The proliferation of solar power plants has begun to have an impact on utility grid operation, stability, and security. As a result, several governments have developed additional regulations for solar photov.
Based on the above analysis, it can be concluded that the harmonic amplification coefficients of the whole grid-connected system in the whole frequency band are all around 1 when the grid contains background harmonics, indicating that the grid-connected photovoltaic inverter system has no harmonic governance ability.
Controllers Reference Frames In grid-tied PV systems, inverter plays a prominent role in energy harvesting and integration of grid-friendly power systems. The reliability, performance, efficiency, and cost-effectiveness of inverters are of main concern in the system design and mainly depend on the applied control strategy.
Grid-connected PV inverters have traditionally been thought as active power sources with an emphasis on maximizing power extraction from the PV modules. While maximizing power transfer remains a top priority, utility grid stability is now widely acknowledged to benefit from several auxiliary services that grid-connected PV inverters may offer.
The coupling of PV inverters connected to the grid through phase-locked loops (PLL) and voltage-current controllers is enhanced in the case of a weak grid. This in turn, brings a series of wide-frequency domain multi-timescale stability problems to the operation of large-scale power plants .
However, these methods may require accurate modelling and may have higher implementation complexity. Emerging and future trends in control strategies for photovoltaic (PV) grid-connected inverters are driven by the need for increased efficiency, grid integration, flexibility, and sustainability.
Using the output impedance of PV inverters in the positive and negative sequence coordinate system, a passive impedance network of PV inverter grid-connected system is established, and the harmonic voltage amplification coefficient of PCC is enhanced.
● A 48V off grid PV Inverter with Microchip control for lead acid and lithium iron phosphate batteries. ● Pure sine wave output, utility input single phase +G, inverter efficiency over 90%.
A 5kw off grid solar inverter is a device that works with lithium battery or lead acid battery and provides uninterrupted power supply support for various fields like communication, industry equipment, military vehicles, and solar generating. This specific model is produced by the brand ELEC, which is a part of Sunerise Energy and focuses on R&D and production of off-grid inverters.
After the panel produces the power, the solar inverter is the second most crucial component of a solar array. A 5kw Inverter receives DC input voltage from the PV panels and turns it into AC power supply. A typical solar inverter involves a step-up transformer, voltage regulator, Mosfet driver, and various other small electronics components.
Explore the Growatt 5kW Off-Grid Inverter SPF 5000 ES—stackable, efficient, and reliable for flexible off-grid power in residential or remote setups.
The 40kW inverter for off-grid use features high-quality pure sine wave AC output and a 3 phase 4 wire connection. It has a no battery design, a wide DC input voltage range, an LCD display, and converts DC power to AC power in solar power systems.
An on-grid 5kw inverter is easy to maintain and converts the direct current to alternating current for powering domestic appliances and even commercial equipment. These solar inverters typically offer high efficiency of around 93% to 96%. Also, the warranty period of these inverters is around 5-10 years.
Growatt 5000ES multifunctional off-grid solar inverter, integrated with a MPPT solar charge controller, a high-frequency pure sine wave inverter, and a UPS function module all in one machine. Perfect for off-grid backup power and self-consumption applications. *Does your jurisdiction require specific certifications?
There are mainly three types of solar inverters: 1. String inverters 2. Microinverters 3. Central inverters String inverters are the most commonly used type of inverters in residential and small commercial solar panel systems. They are called “string” inverters because they work by. Central inverters, also known as large-scale or utility-scale inverters, are used in large commercial and industrial solar panel systems. They are called “central” inverters because they are located in a centralized location and convert the DC power generated by. Microinverters are a type of inverter that are installed directly on each individual solar panel. Unlike string inverters, which convert the DC power generated by a series of panels into AC power, microinverters convert the DC power generated by each.
INVT is a Chinese company that was founded in 2001 and is headquartered in Shenzhen, China. It is one of the top solar inverter manufacturers in China. The company specializes in the development, production, and sales of solar inverters, energy storage systems, and related products.
Huawei Technologies Co., Ltd., a global leader in information and communications technology (ICT) and consumer electronics, is also a major player in the solar energy industry. The company, headquartered in Shenzhen, China, is renowned for its advanced technology solutions, including its line of high-efficiency solar inverters.
Sungrow offers a wide range of solar inverters, including string inverters, central inverters, and modular inverters. They also specialize in energy storage systems and hybrid inverters that integrate solar power with storage solutions. Sungrow's portfolio extends to floating PV systems, wind energy converters, and hydrogen production equipment.
String inverters are cost-effective and easy to install, making them a popular choice for small to medium-sized solar panel systems. However, if one panel in the series fails, the entire string will not produce power, so the system's efficiency can be impacted.
GoodWe is a leading solar inverter manufacturer, recognized as one of the top ten inverter companies in China and globally. They specialize in residential and commercial solar inverters, offering a range of products from 0.7kW to 250kW, providing solutions for clean electricity generation for solar-powered homes.
China is one of the largest manufacturers of solar inverters in the world, and has a large pool of manufacturers and suppliers. This means that there is a wide variety of solar inverters available from different manufacturers, which can provide a competitive advantage for those looking to source from China.
It's a device that converts direct current (DC) electricity, which is what a solar panel generates, to alternating current (AC) electricity, which the electrical grid uses.
Grid-connected PV inverters have traditionally been thought as active power sources with an emphasis on maximizing power extraction from the PV modules. While maximizing power transfer remains a top priority, utility grid stability is now widely acknowledged to benefit from several auxiliary services that grid-connected PV inverters may offer.
Answers: Grid-connected PV inverters need to synchronize their output with the utility and be able to disconnect the solar system if the grid goes down. (1) A system that is designed to supplement grid power and not replace it at any time does not need backup, so installation is simplified.
Grid connected PV systems always have a connection to the public electricity grid via a suitable inverter because a photovoltaic panel or array (multiple PV panels) only deliver DC power. As well as the solar panels, the additional components that make up a grid connected PV system compared to a stand alone PV system are:
1. Introduction to grid-connected solar inverter system Photovoltaic system is a device that converts solar energy into electricity, which is mainly composed of solar panels (modules), inverters, racking, cables and other electrical equipment.
Grid-tied inverters are the critical element in a grid-tied renewable power system. They're most widely used in Photovoltaic systems. A photovoltaic solar system is the most efficient and popular form of renewable power. The term grid-tied means that the house is still attached to the local electricity grid.
By now, you should have a good idea of how solar inverter systems work and why they're important. In a grid-connected PV system, solar panels capture sunlight and convert it into direct current (DC). The inverter then turns that DC into alternating current (AC) that your home and the grid can use.
A monocrystalline solar panelis a solar panel comprising monocrystalline solar cells. The panel derives its name from a cylindrical silicon ingot grown from single-crystal silicon of high purity in the same way as a semiconductor. As the cell is constituted of a single crystal, it provides the. As mentioned above, monocrystalline solar panelsget their name from how they are made. Each of the individual solar cells contains a silicon wafer that is made of a single crystal of. When sunlight falls on the monocrystalline solar panel, the cells absorb the energy, and through a complicated process create an electric field. This. Monocrystalline solar cells are among the three types of materials that exhibit photovoltaic properties. The other two are polycrystalline solar cells and amorphous or thin-film solar. Monocrystalline solar panelsusually have the highest efficiency and power capacity out of all types of solar panels. Monocrystalline.
[PDF Version]Monocrystalline Solar PV Panels - How do they differ? Monocrystalline and polycrystalline solar panels are two of the most common types of photovoltaic panels used in solar energy systems. While both types harness the sun's energy to generate electricity, there are distinct differences in their construction, performance, and efficiency.
Solar cells in monocrystalline solar panels are created from a single silicon crystal, whereas solar cells in polycrystalline solar panels are made from numerous silicon pieces melted together. Some of the major factors on which these two types of solar panels differ are:
Monocrystalline panel efficiencies can range from 17% to 20%. Because monocrystalline solar cells are made out of a single crystal of silicon, electrons can flow easier through the cell, which makes the PV cell efficiency higher than other types of solar panels.
Usually, a monocrystalline panel will contain either 60 or 72 solar cells, depending on the size of the panel. Most residential installations use 60-cell monocrystalline silicon panels. When sunlight falls on the monocrystalline solar panel, the cells absorb the energy, and through a complicated process create an electric field.
Linquip is one of the best sources in the industry for information about monocrystalline solar panels, related equipment, and their installation, use, and maintenance. We at Linquip are always available to help you with any questions or concerns that you may have regarding solar panels or if you need any assistance with them in the future.
Monocrystalline solar cells are among the three types of materials that exhibit photovoltaic properties. The other two are polycrystalline solar cells and amorphous or thin-film solar panels. Monocrystalline solar cells' characteristics are as follows:
A solar combiner box 2 in 1 out is a specialized electrical enclosure used in photovoltaic (PV) systems. It serves to combine the outputs of two separate solar panel strings into a single output.
To run two inverters from one solar array, you need to make sure the inverters and the solar panels' output are compatible, then either connect the inverters in parallel for more capacity and redundancy or configure them independently to handle different energy loads.
Inefficiencies and Compromised Effectiveness: If you try to connect two inverters to one solar panel, it's like trying to use two faucets with one water source. It can lead to problems. Connecting two inverters to the same solar panel may cause inefficiencies and compromise the effectiveness of energy harnessing.
Offering a dual inverter setup on a single solar array could be the game-changer your business needs to address these challenges. This setup not only increases the capacity of the solar system, but also adds redundancy that can protect against downtime and optimize energy distribution across different loads.
The goal is to match each inverter with a section of the solar array that works best for its capacity and what it does, so you get the most energy production and distribution. Use combiner boxes if you need to manage connections from multiple panels before they connect to the inverters. This makes wiring easier and safer.
You can configure the inverters in one of the following ways depending on your system's needs: Parallel Configuration: In a parallel configuration, both inverters are connected to the same solar panels, increasing system capacity to handle high or fluctuating energy demands.
Independent Configuration: In an independent configuration, each inverter connects to separate sections of the solar array, allowing them to manage different energy loads—like heavy machinery during the day and lighting at night—making power distribution more efficient and adapting to different energy needs throughout the day. 3. Installation Steps
The rule of thumb is to size your inverter 1. In some cases, you may need to use multiple inverters to meet your power needs or increase your system's voltage.
A 4.5 kW array (or ten 450-watt solar panels) would just about cover your consumption. The type of solar panels you choose can also impact the size of the inverter you need. Different types of solar panels have different wattage ratings and efficiency levels. The three main types of solar panels are monocrystalline, polycrystalline, and thin film.
Here's a quick reference chart: This inverter size chart helps in selecting the right solar inverter based on load requirements. When choosing an inverter, ensure it matches your solar panel capacity and battery bank for optimal efficiency. The PV inverter size must align with the solar array's capacity and the energy demands of your system.
A solar inverter sizing calculator is a tool used to determine the appropriate size of a solar inverter for your solar power system based on the total power consumption of connected appliances and the size of your solar panel array. It ensures the inverter can handle the peak loads efficiently. 2.
Total capacity = 20 x 500 = 10,000 watts or 10 kW The industry standard suggests that the inverter's capacity should be between 80% to 125% of the solar panels' capacity. For example, if your panels generate 10 kW: Minimum inverter size = 10,000 x 0.8 = 8 kW Maximum inverter size = 10,000 x 1.25 = 12.5 kW
Sometimes, installers might suggest a 3.6kW inverter even if your system requires a larger one. This often is to simplify the G98 application process, the standard grid connection procedure for small-scale solar systems in the UK. While a 3.6kW inverter can facilitate grid approval, it may not align with your actual energy needs.
The size of your solar inverter can be larger or smaller than the DC rating of your solar array, to a certain extent. The array-to-inverter ratio of a solar panel system is the DC rating of your solar array divided by the maximum AC output of your inverter. For example, if your array is 6 kW with a 6000 W inverter, the array-to-inverter ratio is 1.
In this expert-verified guide, we'll explain how solar inverters work, why choosing the right one matters, and reveal the six best solar inverter brands of 2025—carefully reviewed and handpicked by our team of solar professionals at Paradise Energy.
A hybrid 3 phase solar inverter performs this function while simultaneously charging the solar batteries, saving the excess energy produced during the day. A much smarter device, these hybrid 3 phase inverters can execute various additional functions and have been established as an essential part of the future of solar systems.
Safety features: three phase solar inverters have over-current, short-circuit, DC reverse polarity, and output over-voltage protection. In addition, they offer grid monitoring, insulation resistance monitoring, and more. If you are wondering what the main differences between the two types of inverters are, then allow us to decode them for you:
A 3 phase inverter can function with or without a battery, while a regular inverter cannot function without a battery. – A regular inverter can supply 230 V AC energy to the house through a solar battery when the power fails. Still, a three phase solar inverter can supply the same amount from the battery as well as solar panels.
A 3-phase hybrid inverter is expensive. It contributes 25% – 30% of the expenses incurred while setting up a solar power system. But the price is justified due to the warranty and increased efficiency of the power plant. All in all, hybrid 3 phase inverters are a superpower in the world of solar systems.
The SolarEdge Home Hub is the highest-rated solar inverter on the EnergySage Marketplace, thanks to its top-notch efficiency, solid voltage performance, and extended warranty. It's a 10-kilowatt (kW) optimized string inverter that offers the best of both worlds: plenty of output power and panel-level optimization.
We review the best grid-connect solar inverters from the worlds leading manufacturers Fronius, SMA, SolarEdge, Fimer, Sungrow, Huawei, Goodwe, Solis and many more to decide who offers the highest quality and most reliable solar string inverters for residential and commercial solar.
In this expert-verified guide, we'll explain how solar inverters work, why choosing the right one matters, and reveal the six best solar inverter brands of 2025—carefully reviewed and handpicked by our team of solar professionals at Paradise Energy.
Inverters used in photovoltaic applications are historically divided into two main categories: 1. Standalone inverters 2. Grid-connected inverters Standalone inverters are for the applications where the PV plant is not connected to the main energy distribution network. The. Let's now focus on the particular architecture of the photovoltaic inverters. There are a lot of different design choices made by. The first important area to note on the inverter after the input side is the maximum power point tracking (MPPT) converter. MPPT converters are DC/DC converters that have the specific purpose of maximizing the 1 power produced by the PV generator. Note. Next, we find the “core” of the inverter which is the conversion bridge itself. There are many types of conversion bridges, so I won't cover different bridge solutions, but focus instead on the bridge's general workings. In Figure 2, a three-phase inverter is. The most common method to achieve the MPPT algorithm's continuous hunting for the maximum power point is the “perturb and observe”.
[PDF Version]This article introduces the architecture and types of inverters used in photovoltaic applications. Inverters used in photovoltaic applications are historically divided into two main categories: Standalone inverters are for the applications where the PV plant is not connected to the main energy distribution network.
On the other, it continually monitors the power grid and is responsible for the adherence to various safety criteria. A large number of PV inverters is available on the market – but the devices are classified on the basis of three important characteristics: power, DC-related design, and circuit topology.
In order to couple a solar inverter with a PV plant, it's important to check that a few parameters match among them. Once the photovoltaic string is designed, it's possible to calculate the maximum open-circuit voltage (Voc,MAX) on the DC side (according to the IEC standard).
It is based on the same best-in-class power conversion platform as our AMPS solutions, enabling greater scalability and flexibility. Hitachi Energy's Photovoltaic Inverter (PVI) station provides you with advanced control and power capabilities that are designed to meet complex technical requirements and the most challenging grid codes.
One-phase inverters are usually used in small plants, in large PV plants either a network consisting of several one-phase inverters or three-phase inverters have to be used on account of the unbalanced load of 4.6 kVA.
Typical outputs are 5 kW for private home rooftop plants, 10 – 20 kW for commercial plants (e.g., factory or barn roofs) and 500 – 800 kW for use in PV power stations. 2. Module wiring The DC-related design concerns the wiring of the PV modules to the inverter.
A solar inverter is really a converter, though the rules of physics say otherwise. A solar power inverter converts or inverts the direct current (DC) energy produced by a solar panel into Alternate Current (AC.) Most homes use AC rather than DC energy. DC energy is not safe to use in. The solar process begins with sunshine, which causes a reaction within the solar panel. That reaction produces a DC. However, the newly created DC is not safe to use in the home. Oversizing means that the inverter can handle more energy transference and conversion than the solar array can produce. The inverter. Choosing a solar power inverter is a big decision. Much of the information about selecting an inverter has to do with the challenges that a solar array on your roof would have. For example, is there shade, or is there not sufficient south-facing panels, etc. Other. When it comes to choosing a solar inverter, there is no honest blanket answer. Which one is best for your home or business? That depends on a few factors: 1. How.
[PDF Version]A solar inverter is really a converter, though the rules of physics say otherwise. A solar power inverter converts or inverts the direct current (DC) energy produced by a solar panel into Alternate Current (AC.) Most homes use AC rather than DC energy. DC energy is not safe to use in homes.
This article introduces the architecture and types of inverters used in photovoltaic applications. Inverters used in photovoltaic applications are historically divided into two main categories: Standalone inverters are for the applications where the PV plant is not connected to the main energy distribution network.
There are four main types of solar power inverters: Also known as a central inverter. Smaller solar arrays may use a standard string inverter. When they do, a string of solar panels forms a circuit where DC energy flows from each panel into a wiring harness that connects them all to a single inverter.
Solar panels, while important, are just one part of the solar array—the complete system that produces energy from sunlight. Another essential component is the inverter, and thanks to technological advancements, there are inverter options.
In order to couple a solar inverter with a PV plant, it's important to check that a few parameters match among them. Once the photovoltaic string is designed, it's possible to calculate the maximum open-circuit voltage (Voc,MAX) on the DC side (according to the IEC standard).
Also known as a central inverter. Smaller solar arrays may use a standard string inverter. When they do, a string of solar panels forms a circuit where DC energy flows from each panel into a wiring harness that connects them all to a single inverter. The inverter changes the DC energy into AC energy.
With a robust output capacity of 17kW, this solar on grid inverter is ideal for medium to large-scale commercial applications, providing a reliable and sustainable energy solution.
Normally single phase properties can have up to 5 kilowatts of solar inverter capacity and 3 phase properties can have 15 kilowatts. Larger inverters that are export limited are allowed on a case by case basis. Victoria's Powercor area: Western Victoria, including a large portion of West Melbourne.
Recommended max. PV power Solis 17KW three-phase Dual MPPT inverter offers RS485, WiFi & GPRS connectivity with max efficiency of 98.7%. It ensures reliability, efficiency & affordability. Buy Now!
The Huawei SUN2000-12/15/17/20/25KTL-M5/M2 three-phase grid-tied inverter series is an innovative new range of inverters suitable for both residential and small commercial applications. It has an active AI-powered arcing protection feature which prevents and mitigates electrical hazards.
Grid connected PV inverters are required to have passive islanding detection and protection methods that cause the PV inverter to stop supplying power to the utility grid if the voltage amplitude or the frequency of the point of common coupling (PCC) between the local customer load and the utility grid strays outside of prescribed limits.
Grid-connected PV inverters are electronic devices that convert DC power from photovoltaic (PV) solar panels into AC power that can be fed into the utility grid. They are required to have passive anti-islanding protection methods. These methods cause the PV inverter to stop supplying power to the utility grid if the voltage amplitude or the frequency of the point of common coupling (PCC) between the local customer load and the utility grid strays outside of prescribed limits.
Grid-connected PV inverters have traditionally been thought as active power sources with an emphasis on maximizing power extraction from the PV modules. While maximizing power transfer remains a top priority, utility grid stability is now widely acknowledged to benefit from several auxiliary services that grid-connected PV inverters may offer.
The performance in islanding prevention is determined by the detection time of islanding operation mode. The proposed anti-islanding protection was simulated under complete disconnection of the photovoltaic inverter from the electrical power system, as well as under grid faults as required by new grid codes. 1. Introduction
The control design of this type of inverter may be challenging as several algorithms are required to run the inverter. This reference design uses the C2000 microcontroller (MCU) family of devices to implement control of a grid connected inverter with output current control.
Automatic recovery of the grid-connected protection: After the grid-tied inverter stops supplying power to the grid because of the fault of the grid, the grid-tie inverter should be able to automatically send power to the grid 5 min after the grid voltage and frequency return to the normal range for 20s.
However, these methods may require accurate modelling and may have higher implementation complexity. Emerging and future trends in control strategies for photovoltaic (PV) grid-connected inverters are driven by the need for increased efficiency, grid integration, flexibility, and sustainability.
This paper proposes a closed photovoltaic inverter structure based on heat pipe and liquid cooling which overcomes the noise, dust and other problems caused by traditional air-cooling heat dissipation method and reduces cost of the volume occupied inside the body.
al power. If the large amount of heat generated during the operation of the inverter is not dissipated in time, excessive temperature rise will reduce the safety of the devices. This paper proposes a closed PV inverter structure based on heat pipe and li uid cooling which overcomes the noise, dust and other problems caused by tradit
e actual operation of the PV inverter, the thermal load on the inverter module is dynamic rather than constant, the heat loss is positively correlated with solar irradiance. Thus, this section conducts simulations to assess the maximum junction tem
per introduces a thermal management solution for high-power photovoltaic inverter cabinets based on heat pipes, aiming to achieve encl sed, efficient, and safe heat dissipation. The f asibility of this cooling approach is substantiated through measurements of th
ing heat dissipation a hot point in electronic component research.For electronic devices such as photovoltaic inverters,
he most common heat dissipation method is air cooling. For some low-power inverters, natural convection demonstrates its advantages in terms of cost and space utilization [5-7]. However, with the rise of the inverter's power, natural c
ion structure can effectively dissipate the heat inside the cabinet. The impact of two different types of heat sink used for power modules on temperature uniformity was studied. The results indicated that the 9-heat pipe type heat si k has better heat dissipation and uniform hot spots performance, the maximum heat source tempe fo mance of the
A grid connected PV system is one where the photovoltaic panels or array are connected to the utility grid through a power inverter unit allowing them to operate in parallel with the electric utility grid.
Photovoltaic grid-connected inverter is an essential key component in photovoltaic power generation system. It is mainly used in the special inverter power supply in the field of solar photovoltaic power generation.
[A Complete Guide] A grid-connected photovoltaic (PV) system, also known as a grid-tied or on-grid solar system, is a renewable energy system that generates electricity using solar panels. The generated electricity is used to power homes and businesses, and any excess energy can be fed back into the electrical grid.
Grid-connected PV inverters have traditionally been thought as active power sources with an emphasis on maximizing power extraction from the PV modules. While maximizing power transfer remains a top priority, utility grid stability is now widely acknowledged to benefit from several auxiliary services that grid-connected PV inverters may offer.
Grid connected PV systems with batteries are a type of renewable energy system that combine photovoltaic (PV) panels and battery storage to generate and store electricity.
In order to provide grid services, inverters need to have sources of power that they can control. This could be either generation, such as a solar panel that is currently producing electricity, or storage, like a battery system that can be used to provide power that was previously stored.
String Inverter System: This is the most common type of grid-connected PV system. It uses a string inverter to convert DC electricity from the solar panels to AC electricity for use in the home or business. Micro-Inverter System: This type of grid-connected PV system uses micro-inverters attached to each panel.